CVE-2012-6438

published 24 Jan 2013 · updated 3 Jun 2026

Rockwell Automation ControlLogix PLC Improper Input Validation

8.0HighCVSS 7.5EPSS 36%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 36%. No fixed version is recorded.

The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
Rockwell Automation=All, <=19, <=20, <=18, =1100, =1400

Timeline

Every event on this vulnerability

Embed

A live severity badge for an advisory, README or ticket

CVE-2012-6438 severity on Zeptric[![CVE-2012-6438](https://zeptric.io/badge/cve/CVE-2012-6438.svg)](https://zeptric.io/cve/CVE-2012-6438)