CVE-2017-18044

published 19 Jan 2018 · updated 5 Aug 2024

A Command Injection issue was discovered in ContentStore/Base/CVDataPipe.dll in Commvault before v11 SP6

6.0MediumEPSS 69%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 69%. No fixed version is recorded.

A Command Injection issue was discovered in ContentStore/Base/CVDataPipe.dll in Commvault before v11 SP6. A certain message parsing function inside the Commvault service does not properly validate the input of an incoming string before passing it to CreateProcess. As a result, a specially crafted message can inject commands that will be executed on the target operating system. Exploitation of this vulnerability does not require authentication and can lead to SYSTEM level privilege on any system running the cvd daemon. This is a different vulnerability than CVE-2017-3195.

Timeline

Every event on this vulnerability

Embed

A live severity badge for an advisory, README or ticket

CVE-2017-18044 severity on Zeptric[![CVE-2017-18044](https://zeptric.io/badge/cve/CVE-2017-18044.svg)](https://zeptric.io/cve/CVE-2017-18044)