A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions…
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 2%. Fixed in Capital Embedded AR Classic *, Capital Embedded AR Classic V2303, Nucleus ReadyStart V3 V2017.02.4 and 2 more.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Siemens | Capital Embedded AR Classic | <V2303 | *, V2303 |
| Siemens | Nucleus NET | =All versions | |
| Siemens | Nucleus ReadyStart V3 | <V2017.02.4 | V2017.02.4 |
| Siemens | Nucleus ReadyStart V4 | <V4.1.0 | V4.1.0 |
| Siemens | Nucleus Source Code | * |