A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions…
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 2%. Fixed in Capital Embedded AR Classic *, Capital Embedded AR Classic V2303, Nucleus ReadyStart V3 V2017.02.4 and 2 more.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Siemens | Capital Embedded AR Classic | <V2303 | *, V2303 |
| Siemens | Nucleus NET | =All versions | |
| Siemens | Nucleus ReadyStart V3 | <V2017.02.4 | V2017.02.4 |
| Siemens | Nucleus ReadyStart V4 | <V4.1.0 | V4.1.0 |
| Siemens | Nucleus Source Code | * |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Siemens, strongest first
Embed
A live severity badge for an advisory, README or ticket