CVE-2021-31346

published 9 Nov 2021 · updated 11 Mar 2025

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions…

8.2HighCVSS 8.2EPSS 2%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 2%. Fixed in Capital Embedded AR Classic * and Capital Embedded AR Classic V2303.

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
SiemensCapital Embedded AR Classic<V2303*, V2303
SiemensPLUSCONTROL 1st Gen=All versions
SiemensSIMOTICS CONNECTAll versions <V0.5.0.0, All versions <V1.0.0.0

Timeline

Every event on this vulnerability

Related

Other vulnerabilities in Siemens, strongest first

10.0CriticalCISA KEVPublic exploit
10.0CriticalCISA KEVPublic exploit

Embed

A live severity badge for an advisory, README or ticket