published 9 Nov 2021 · updated 11 Mar 2025
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions…
6.5MediumCVSS 6.5EPSS 2%
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 2%. Fixed in Capital Embedded AR Classic * and Capital Embedded AR Classic V2303.
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303). The DHCP client application does not validate the length of the Domain Name Server IP option(s) (0x06) when processing DHCP ACK packets. This may lead to Denial-of-Service conditions. (FSMD-2021-0011)
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Siemens | Capital Embedded AR Classic | <V2303 | *, V2303 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Siemens, strongest first
10.0CriticalCISA KEVPublic exploit
10.0CriticalCISA KEVPublic exploit
10.0CriticalCISA KEVPublic exploit
Embed
A live severity badge for an advisory, README or ticket