CVE-2022-34760

published 13 Jul 2022 · updated 17 Sep 2024

A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the…

7.5HighCVSS 7.5EPSS 1%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 1%. Fixed in OPC UA Modicon Communication Module V1.10.

A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
Schneider ElectricOPC UA Modicon Communication Module>=BMENUA0100 <V1.10V1.10
Schneider ElectricX80 advanced RTU Communication Module=BMENOR2200H V1.0

Timeline

Every event on this vulnerability

Related

Other vulnerabilities in Schneider Electric, strongest first

Embed

A live severity badge for an advisory, README or ticket

CVE-2022-34760 severity on Zeptric[![CVE-2022-34760](https://zeptric.io/badge/cve/CVE-2022-34760.svg)](https://zeptric.io/cve/CVE-2022-34760)