Cisco Industrial Network Director Command Injection Vulnerability
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 14%. No fixed version is recorded.
A vulnerability in the web UI of Cisco IND could allow an authenticated, remote attacker to execute arbitrary commands with administrative privileges on the underlying operating system of an affected device. This vulnerability is due to improper input validation when uploading a Device Pack. An attacker could exploit this vulnerability by altering the request that is sent when uploading a Device Pack. A successful exploit could allow the attacker to execute arbitrary commands as NT AUTHORITY\SYSTEM on the underlying operating system of an affected device. Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Cisco | Industrial Network Director | =1.0.0, =1.0.1, =1.1.0, =1.1.1, =1.10.0, =1.11.0, =1.11.1, =1.11.2, =1.2.0, =1.3.0, =1.3.1, =1.4.0, =1.5.0, =1.5.1, =1.6.0, =1.6.1, =1.7.0, =1.7.1, =1.8.0, =1.9.0 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Cisco, strongest first
Embed
A live severity badge for an advisory, README or ticket