SICK InspectorP61x and SICK InspectorP62x are vulnerable for firmware modification

8.8HighCVSS 8.8EPSS 0%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in <5.0.0.

Since the firmware update is not validated, an attacker can install modified firmware on the device. This has a high impact on the availabilty, integrity and confidentiality up to the complete compromise of the device.

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
SICK<<5.0.0<5.0.0

Timeline