published 28 Oct 2025 · updated 28 Oct 2025
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an aut…
7.5HighCVSS 7.5EPSS 0%
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in 8.9.6.0.
The “Diagnostics Tools” page of the web-based configuration utility does not properly validate user-controlled input, allowing an authenticated user with high privileges to inject commands into the command shell of the TropOS 4th Gen device. The injected commands can be exploited to execute several set-uid (SUID) applications to ultimately gain root access to the TropOS device.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Hitachi Energy | >=8.7.0.0 <8.9.6.0 | 8.9.6.0 |
Timeline
Every event on this vulnerability
Embed
A live severity badge for an advisory, README or ticket