CVE-2025-30002

published 16 Apr 2025 · updated 16 Apr 2025

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2)

8.8HighCVSS 8.8EPSS 1%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 1%. Fixed in TeleControl Server Basic V3.1.2.2.

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
SiemensTeleControl Server Basic<V3.1.2.2V3.1.2.2