CVE-2025-40576

published 13 May 2025 · updated 8 Jul 2025

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0)

4.3MediumCVSS 4.3EPSS 0%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in SCALANCE LPE9403 V4.0 HF0.

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process.

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
SiemensSCALANCE LPE9403<V4.0 HF0V4.0 HF0

Timeline