CVE-2025-57293

published 18 Sep 2025 · updated 5 Nov 2026

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function…

9.8CriticalCVSS 8.8EPSS 2%1 public exploits

A public exploit exists; no exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 2%. No fixed version is recorded.

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
Comfastcf-xr11_firmware=2.7.2

Exploit evidence

1 public sources

Timeline

Every event on this vulnerability

Embed

A live severity badge for an advisory, README or ticket

CVE-2025-57293 severity on Zeptric[![CVE-2025-57293](https://zeptric.io/badge/cve/CVE-2025-57293.svg)](https://zeptric.io/cve/CVE-2025-57293)