GatesAir Flexiva-LX devices on firmware 1.0.13 and 2.0, including models LX100, LX300, LX600, and LX1000, expose sensitive session…
A public exploit exists; no exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. No fixed version is recorded.
GatesAir Flexiva-LX devices on firmware 1.0.13 and 2.0, including models LX100, LX300, LX600, and LX1000, expose sensitive session identifiers (sid) in the publicly accessible log file located at /log/Flexiva%20LX.log. An unauthenticated attacker can retrieve valid session IDs and hijack sessions without providing any credentials. This attack requires the legitimate user (admin) to have previously closed the browser window without logging out.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| gatesair | flexiva_lx1000_firmware | =1.0.13, =2.0 | |
| gatesair | flexiva_lx100_firmware | =1.0.13, =2.0 | |
| gatesair | flexiva_lx300_firmware | =1.0.13, =2.0 | |
| gatesair | flexiva_lx600_firmware | =1.0.13, =2.0 |