CVE-2025-71284

published 30 Apr 2026 · updated 30 Apr 2026

Synway SMG Gateway Management Software OS Command Injection via radius_address

10.0CriticalCVSS 9.8EPSS 6%2 public exploits

2 public exploits exists; no exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 6%. No fixed version is recorded.

Synway SMG Gateway Management Software contains an OS command injection vulnerability in the RADIUS configuration endpoint at /en/9-2radius.php where the radius_address POST parameter is split and interpolated directly into a sed command without sanitization. An unauthenticated remote attacker can inject arbitrary shell commands by submitting a POST request with crafted radius_address, radius_address2, shared_secret2, source_ip, timeout, or retry parameters along with save=1 and enable_radius=1 to achieve remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 (UTC).

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
Synway Information Engineering

Exploit evidence

2 public sources

Timeline

Every event on this vulnerability

Embed

A live severity badge for an advisory, README or ticket

CVE-2025-71284 severity on Zeptric[![CVE-2025-71284](https://zeptric.io/badge/cve/CVE-2025-71284.svg)](https://zeptric.io/cve/CVE-2025-71284)