Lantronix XPress-DR 8.1.0.0 Unauthenticated Configuration Write via UDP 30718
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 1%. No fixed version is recorded.
Lantronix XPress-DR and XPress-DR-I (CoBos-family) firmware through 8.1.0.0 contains a missing authentication vulnerability that allows remote attackers to read and persistently overwrite device configuration by sending crafted frames to the unauthenticated UDP configuration protocol on port 30718. Attackers can send a type 0xF8 query to read live configuration data and a type 0xFD frame with exactly 0x78 body bytes to rewrite the device IP address and serial-channel forwarding records, causing changes to commit to EEPROM and persist across reboots. The XPress-DR product series reached end-of-life/end-of-support in February 2025.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Lantronix | XPress-DR | <=8.1.0.0 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Lantronix, strongest first
Embed
A live severity badge for an advisory, README or ticket