CVE-2026-118052

published 2 Nov 2026 · updated 2 Nov 2026

Module Manager loaders leave the manager mutex held when a module preamble's sizes overflow, blocking every later module operation

6.8MediumCVSS 6.8EPSS 0%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. No fixed version is recorded.

In Eclipse ThreadX versions 6.0.1 through 6.5.2.202603, the Module Manager loaders return an overflow error without releasing the Module Manager mutex when a module preamble declares a data or stack size that overflows the allocation arithmetic. Loading such an image blocks every later module load, start, stop and unload from other threads until the system is reset.

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
Eclipse Foundation>=6.0.1 <=6.5.2.202603

Timeline