FlowIntel Missing Authorization Check Allows Unauthorized Revival of Completed Privileged Cases via Task Reopening
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 1%. Fixed in 4.1.0.
FlowIntel contains an authorization bypass in its task management workflow. When a user reopens a completed task (by toggling its completion state or changing its status to a non-finished value) or creates a new task within a completed privileged case, the parent case is automatically revived (un-completed, status reset to Created, finish date cleared). The system failed to enforce the required Admin or Case Admin privilege check before performing this case revival side effect. A user with basic task-level permissions (e.g., editor, queuer, or queue admin) could trigger the revival of a completed privileged case through the browser interface or the REST API, without holding the elevated role required for case-level operations. This could disrupt case lifecycle management, clear completion metadata, and potentially expose the case to further unauthorized modifications. The vulnerability affects both the browser-based task completion/status-change endpoints and the corresponding API endpoints, as well as the task creation flow. Affected versions: FlowIntel prior to 4.1.0.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| flowintel | <4.1.0 | 4.1.0 |