CVE-2026-19003

published 12 Aug 2026 · updated 13 Aug 2026

MongoDB BI Connector ODBC driver may write outside an allocated buffer when the setup dialog opens a data source with oversized path settings

7.8HighCVSS 7.8EPSS 0%

No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in BI Connector 1.4.9.

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Affected

Vendors, products and packages with version ranges

VendorProductVersionsFixed
MongoDBBI Connector>=1.0.0 <1.4.91.4.9

Timeline

Every event on this vulnerability

Related

Other vulnerabilities in MongoDB, strongest first

Embed

A live severity badge for an advisory, README or ticket

CVE-2026-19003 severity on Zeptric[![CVE-2026-19003](https://zeptric.io/badge/cve/CVE-2026-19003.svg)](https://zeptric.io/cve/CVE-2026-19003)