Junos OS: SRX Series: A specifically malformed GTP message will cause an FPC crash
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in 22.4R3-S8, 23.2R2-S5, 23.4R2-S6 and 3 more.
An Improper Locking vulnerability in the GTP plugin of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (Dos). If an SRX Series device receives a specifically malformed GPRS Tunnelling Protocol (GTP) Modify Bearer Request message, a lock is acquired and never released. This results in other threads not being able to acquire a lock themselves, causing a watchdog timeout leading to FPC crash and restart. This issue leads to a complete traffic outage until the device has automatically recovered. This issue affects Junos OS on SRX Series: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5, * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S3, * 24.4 versions before 24.4R2-S2, * 25.2 versions before 25.2R1-S1, 25.2R2.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Juniper Networks | <22.4R3-S8, >=23.2 <23.2R2-S5, >=23.4 <23.4R2-S6, >=24.2 <24.2R2-S3, >=24.4 <24.4R2-S2, >=25.2 <25.2R1-S1, 25.2R2 | 22.4R3-S8, 23.2R2-S5, 23.4R2-S6, 24.2R2-S3, 24.4R2-S2, 25.2R1-S1, 25.2R2 |