Junos OS: SRX and MX Series: When TCP packets occur in a specific sequence flowd crashes
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in 22.4R3-S7, 23.2R2-S3, 23.4R2-S4 and 1 more.
A Double Free vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX and MX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). On all SRX and MX Series platforms, when during TCP session establishment a specific sequence of packets is encountered a double free happens. This causes flowd to crash and the respective FPC to restart. This issue affects Junos OS on SRX and MX Series: * all versions before 22.4R3-S7, * 23.2 versions before 23.2R2-S3, * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Juniper Networks | <22.4R3-S7, >=23.2 <23.2R2-S3, >=23.4 <23.4R2-S4, >=24.2 <24.2R2 | 22.4R3-S7, 23.2R2-S3, 23.4R2-S4, 24.2R2 |