A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6)
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in SINEC INS V1.0 SP2 Update 6.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Siemens | SINEC INS | <V1.0 SP2 Update 6 | V1.0 SP2 Update 6 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Siemens, strongest first
Embed
A live severity badge for an advisory, README or ticket