A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC…
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in SIMATIC IPC BX-21A V31.01.13, SIMATIC IPC RW-543A V1.1.4 and SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G V28.01.15.
A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Siemens | SIMATIC IPC BX-21A | <V31.01.13 | V31.01.13 |
| Siemens | SIMATIC IPC RW-543A | <V1.1.4 | V1.1.4 |
| Siemens | SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G | <V28.01.15 | V28.01.15 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in Siemens, strongest first
Embed
A live severity badge for an advisory, README or ticket