Lantronix Autonomous Out-of-Band Devices WebSSH SSRF via Username Truncation
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 1%. Fixed in EMG7500 9.7.0.1, EMG8500 9.7.0.1, SLC8000 9.7.0.3 and 1 more.
Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882 contain a server-side request forgery vulnerability in the WebSSH/WebTelnet listener that allows unauthenticated attackers to cause the affected device to establish SSH connections to attacker-controlled endpoints. The custom shellinaboxd builds its SSH connection target using a snprintf call with user-supplied input; by supplying an overlong username string an attacker causes the device IP suffix to be truncated, redirecting the resulting connection to an arbitrary host. Attackers can use this capability to enumerate or communicate with internal network endpoints that would otherwise be inaccessible.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Lantronix | EMG7500 | <9.7.0.1 | 9.7.0.1 |
| Lantronix | EMG8500 | <9.7.0.1 | 9.7.0.1 |
| Lantronix | SLB882 | ||
| Lantronix | SLC8000 | <9.7.0.3 | 9.7.0.3 |
| Lantronix | SLC9000 | <9.7.0.2 | 9.7.0.2 |