PicoTronica e-Clinic Healthcare System ECHS echs.js hard-coded credentials
A public exploit exists; no exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. No fixed version is recorded.
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| PicoTronica | =5.7 |
Exploit evidence
1 public sources
Timeline
Every event on this vulnerability
Embed
A live severity badge for an advisory, README or ticket