HTTP/1 server crash due to MaxBytesReader header race in net/http
No exploitation in the wild has been reported. EPSS puts the chance of exploitation in the next 30 days at 0%. Fixed in 1.26.11, 1.27.4 and stdlib 1.27.4.
For HTTP/1 servers, when MaxBytesReader's limit is exceeded, "Connection: close" header is automatically set without synchronization, which might race with another header being set explicitly in the server handler. As a result, an HTTP/1 server that utilizes MaxBytesReader or MaxBytesHandler can crash due to runtime panic if its handler reads the request body concurrently with writing the response header.
Affected
Vendors, products and packages with version ranges
| Vendor | Product | Versions | Fixed |
|---|---|---|---|
| Go standard library | <1.26.11, >=1.27.0-0 <1.27.4 | 1.26.11, 1.27.4 | |
| go: stdlib | >=1.27.0-0 <1.27.4 | 1.27.4 |
Timeline
Every event on this vulnerability
Related
Other vulnerabilities in stdlib (Go), strongest first
Embed